TM 5-4520-253-13
TEST PC BOARD ASSEMBLY (CONT)
Table 4-3. PC Board Testing Continued
(1)
(2)
(3)
Test For/
Meter
Setting
(4)
Probe
No. 1
Component Circuit
Upper Thermostat
(Fan Side)
Heater Mode
Power Cable:
Plugged
HEATER-OFF-
FAN Switch:
HEATER
Voltage
Grey Wire
(23)
Any White
110 V ac
Wire or
Terminal
Connector
Any White
110 V ac
Wire or
Terminal
Connector
Lower Thermostat
(Discharge Side)
Power Cable:
Plugged
HEATER-OFF-
FAN Switch:
HEATER
Power Cable:
Plugged
HEATER-OFF-
FAN Switch:
HEATER
Voltage
Grey Wire
(24)
Lower Thermostat
(Discharge Side)
Any White
110 V ac
Wire or
Terminal
Connector
Voltage
Red/White
Wire (25)
Blue Wire
(26)
Fuel Solenoid
Power Cable:
Plugged
HEATER-OFF
FAN Switch:
HEATER
Voltage
Ventilating Air
Motor
Power Cable:
Plugged
HEATER-OFF-
FAN Switch:
HEATER
Voltage
White Wire
(From PC
Board)
(28)
Red Wire
110 V ac
Combustion Blower
Power Cable:
Plugged
HEATER-OFF-
FAN Switch:
HEATER
Voltage
White Wire
(30)
Yellow Wire
110 V ac
(31)
Transformer
Power Cable:
Plugged
HEATER-OFF-
FAN Switch:
HEATER
Voltage
White Wire
(32)
Yellow Wire
110 V ac
(33)
Change 2 4-32.1/(4-32.2 blank)
( 5)
P r o b e
No.2
( 6 )
M e t e r
I n d i -
cation
Green Wire
(27)
28 V dc
(29)