THERMOSTATIC SWITCH (FLAME DETECTOR SWITCH) REPAIR - STEWART-WARNER 10560C24,
10560M, 10560M24B1, 10560G - Continued
LOCATION
ITEM
ACTION
REMARKS
ASSEMBLY
4. Flame detector switch (1)
Ceramic rod (2)
Install.
5.
Flame detector switch (1)
Install.
6.
Spring (3)
Install.
CAUTION
7.
Do not overtlghten adjusting screw. Ceramic rod Is easily damaged.
Adjusting screw (4) and
Screw in until switch (1) touches
self-locking nut (5)
rod (2).
NOTE
FOLLOW-ON MAINTENANCE: Install and adjust flame detector switch (page 2-43,
2-44).
TASK ENDS HERE
3-73
TM 9-2540-205-24&P