TM 9-4520-251-14
4-48 IGNITION CABLE
This task covers:
a. Inspection
b. Repair
INITIAL SETUP
Tools
Equipment Condition Para
Condition Description
Tool kit, service, refrigeration unit
447
High tension cable removed
(Appendix B, Section Ill, Item 1)
from heat exchanger case.
Materials/Parts
Ignition cable
Connector
General Safety Instructions
Heat exchanger casing and combustor may become dangerously hot.
Do not touch heater parts during or immediately after operation.
Perform maintenance only after heater has cooled.
Location/Item
Action
Remarks
INSPECTION
1. High tension
Inspect high tension cable (1) for damage.
cable
2. Spring, stud,
Check for burned spring (2) and stud (3). Inspect
and connector
connector (4) for tears, abrasion, or other damage.
3. Cable wire
Be sure cable wire (5) is properly connected to
spring (2)
4-121