TM 9-4520-257-12&P 0002 00
0002 00-7/(8 Blank)
Performance Specification Data
WARNING
Fire or Explosion
Do not use motor oil, cleaning solvents, or any other fuel not authorized
for use in the H-45. Use of an unauthorized fuel may result in fire or
explosion.
Fuel Types Usable For Heater Operation:
Solid Fuel Mode ......................................................................................................... Wood, coal
Liquid Fuel Mode..................................JP-8; DF-A, DF-1, DF-2; JP-5; kerosene; Jet A-1; Jet A;
gasoline (emergency only); JP-4 (emergency only)
Liquid Fuel Consumption:
Rate of fuel consumption at maximum firing rate:
DF-1, DF-2 .................................................... 0.6 gallons/hour (37.85 cubic centimeters/minute)
JP-5, JP-8, DF-A ......................................... 0.63 gallons/hour (39.74 cubic centimeters/ minute)
Outputs:
Burner firing rate (setting dependent)....................................................20,000 to 45,000 BTU/hr
Environmental:
Operating temperatures ............................................................ -600F to +500F (-510C to +100C)
Operating elevations ..................................................................... to 6,000 feet above sea level
COMMON TOOLS AND EQUIPMENT
For authorized common tools and equipment, refer to the Modified Table of Organization and Equipment
(MTOE); Common Table of Allowances (CTA) 50-970, Expendable/Durable Items (Except: Medical,
Class V, Repair Parts, and Heraldic Items); or CTA 8-100, Army Medical Department Expendable/Durable
Items, as applicable to your unit.
There are no special tools; test measurement and diagnostic equipment (TMDE); and support equipment
for the H-45.
Repair parts are listed and illustrated in the repair parts and special tools lists (RPSTLs) located in
WP 0042 00 through WP 0046 00.
END OF WORK PACKAGE