TM 9-4520-258-14
4-16. REMOTE CONTROL THERMOSTAT - continued.
b. Inspection
(1)
Inspect connection for secure mounting, burnt, broken or bent terminals and corrosion.
(2)
Inspect cable for cracked, burnt, or deteriorated insulation and exposed conductor.
(3)
Inspect lug terminal for secure mounting and signs of burning and corrosion.
c. Repair (Refer to Figure 4-11)
(1)
Repair of remote thermostat box is limited to replacement if damaged.
(2)
Repair of cable assembly consists of replacing damaged parts with new parts. If cable (1) is damaged the
complete assembly must be replaced.
(a)
Cut strap (2) from connector plug (3) and remove cover assembly (4).
(b)
Remove two screws (5), two nuts (6) and two saddles (7).
(c)
Unscrew clamp (8) and slide clamp, grommet follower (9), grommet (10), and rubber bushing (11)
down on cable (1).
(d)
Unscrew sleeve (12) from connector plug (3) and down on cable (1).
(e)
Tag three wires (13), (14) and (15).
(f)
Cut connector plug (3) from cable (1).
(g)
Slide sleeve (12), bushing (11), grommet (10), grommet follower (9), and clamp (8) from cable (1).
4-60