TM 9-4520-258-14
4-16.
REMOTE CONTROL THERMOSTAT - continued.
c.
Repair - continued (Refer to Figure 4-11)
(h)
Slide cable clamp (8), grommet follower (9), grommet (10), rubber bushing (11), and sleeve
assembly (12) on cable (1).
(i)
Strip .75 inch of insulation from cable (1) to expose insulated conductor wires (13), (14) and (15).
(j)
Strip .25 inch of insulation from insulation conductor wires (13), (14) and (15) Solder wires into
connector plug (3) pins as follows:
1
Black wire (15), P3-AITB2-2 to pin A.
2
White wire (14), P3-B/TB2-3 to pin B.
3
Green wire (13), P3-C/TB2-1 to pin C.
Figure 4-11. Remote Control Thermostat Repair (Sheet 2 of 3)
4-62