TM 9-4520-271-14
0026 00
ASSEMBLY
Continued
EMI Jumper and Terminal Boards TB1, TB2, and TB3 Installation
NOTE
Procedures are typical for terminal boards TB1, TB2, and TB3 except that only terminal board TB1 has an
EMI jumper. Terminal board TB2 is shown.
1.
Install marker strip (13), terminal board TB2 (12), two screws (11), washers (10), lockwashers (9) (item 27, WP 0062
2.
Install two EMI jumper (5) leads (terminal board TB1 only), jumpers (4), wires (2), and screws (3). Install wires ties as
required. Remove wire marker tags.
3.
Install EMI jumper (5) lead (terminal board TB1 only) under screw (7) and tighten two nuts (6).
WARNING
Acrylic lacquer sealant is flammable. Keep away from open flames or other sources of ignition. Avoid
breathing fumes from sealant. Good general ventilation is normally adequate. Avoid skin contact with
sealant.
4.
Apply light coat of acrylic lacquer sealer to terminal board TB2 (12) terminals.
5.
Close side rear door (1).
0026 00-20