TM 9-4520-271-14
0026 00
ASSEMBLY
Continued
Motor Contactor and Motor Overload Protector Installation
1.
Install gasket (14).
2.
Install mounting plate (6) with two screws (13), four washers (12), two lockwashers (11) (item 27, WP 0062 00), and
nuts (10).
3.
Install motor overload protector (5) onto motor contactor (4) and tighten three setscrews (9).
4.
Connect following ten wires (7) and tighten setscrews (8). Remove wire marker tags.
K2-1? TB1-2 to K2-1
K2-3? TB1-3 to K2-3
K2-5? K2-4 to K2-5
K2-5? K2-4 to K2-4
K2-2? B1-T4, T8 to K2-2
K2-6? B1-T1, T5 to K2-6
K2-13? TB1-3 to K2-13
K2-14? DS1 to K2-14
K2-A1? TB1-4 to K2-A1
K2-A2? TB2-4 to K2-A2
5.
Slide motor contactor (4) and motor overload protector (5) onto mounting plate (6).
6.
Install clamp (3) and tighten setscrew (2).
WARNING
Acrylic lacquer sealant is flammable. Keep away from open flames or other sources of ignition. Avoid
breathing fumes from sealant. Good general ventilation is normally adequate. Avoid skin contact with
sealant.
7.
Apply light coat of acrylic lacquer sealer to electrical connections.
8.
Close side rear door (1).
0026 00-16