TM 9-4520-271-14
0038 00
ASSEMBLY - Continued
Thermostat Control R1 Installation
1.
Install thermostat control R1 (8), O-ring (7), lockwasher (6), and nut (5).
WARNING
Avoid breathing fumes generated by soldering. Eye protection is required. Good general ventilation is
normally adequate.
2.
Solder three wires (1) to thermostat control R1 terminals (4, 3, and 2). Remove wire marker tags.
3.
0038 00-19