TM 9-4931-3151-14&P-2
FRAME 4
Remove Power Supply:
WARNING
A3P1 (1) and A3P2 (2) leads contain voltages that may cause
death on contact even when test set power is off. To avoid
electric shock, connect housing (3) to facility ground.
Ensure no part of body touches metal whiIe removing leads.
Remove leads and touch exposed metal part of lead to
chassis.
1.
Unscrew and take off electrical lead A3P1 (1), lead A3P2 (2), and
connector W1P3 (4) from power supply (5).
2. Unscrew and take out four machine screws (6) with screwdriver.
3. Take power supply (5) out of housing (3).
electrical plug
4. Look at power supply (5) for cracks. If bad, turn in. If OK, set aside for later use.
Follow-on Maintenance:
NOTE: To instalI power supply, refer to task 15.
TASK 4 ENDS HERE
Volume IV
2-168
Para. 2-8, Task 4