T M 9 - 4 9 3 1 - 3 8 1 - 1 4 & P -2
FRAME 7
Remove Electrical Plug Connector P3:
1.
2.
3.
4.
Electron tube in electronic tube assembly (1) is breakable.
Put on faceshield before handling tube assembly (1). Make
sure tube assembly (1) is pointed away from you. If
breakage causes injury, flush wound with freshwater and
notify medic.
NOTE
l
Read paragraph 2-4 on tagging and soldering wires, and
installing insulation sleeving before doing any work.
l
lf connector wires (2) are soldered, go to step 1. If
connector wires (2) are crimped, GO TO FRAME 9.
Put tube assembly (1) in tray so that only connector P3 (3) is exposed. Cover tube
assembly (1) with rags.
Cut off lacing tape (4) with diagonal cutting pliers. Get rid of lacing tape (4).
Carefully cut insulation sleeving (5) off 10 wires (2) with knife. Get rid of sleeving
(5).
Unsolder wires (2) from terminals (6) of connector P3 (3). Turn in connector P3 (3).
GO TO FRAME 8
Volume IV
Para. 2-8, Task 6
2-173