TASK 10. Replace Electrical Plug Connectors A6A1P1, A6A1P2, or A6A1P3.
Applicability: All Models
Common Tools:
Pliers, diagonal cutting
Special Tools:
T M 9 - 4 9 3 1 - 3 8 1 - 1 4 & P -2
Maintenance Kit, electrical connector repair, 12285360
Supplies:
NOTE Expendable supplies are defined in volume 1, appendix C.
Connector, plug, electrical (96906) M83723/75R22-55N (as required)
Connector, plug, electrical (81349) MS3475L22-55PW (as required)
Connector, plug, electrical (96906) MS3475L20-41P (as required)
Pencil, writing (Item 19)
Strap, tiedown, electrical components (as required) (Item 32)
Tag, marker (as required) (Item 34)
Personnel: One
Equipment Condition:
Thermal system controller on a clean work surface.
Preliminary Procedures:
1. Remove thermal system test controller case cover; refer to volume 1, para. 4-17.
2. Remove thermal system test controller; refer to para. 2-5, task 2.
3. Remove power module A6; refer to task 1.
Volume IV
Para. 2-9, Task 10
2-241