c. Installation. Refer to
figure 3-1 and
install the
burner onm the heater body.
grate in the heater body.
d. Test. Light burner to test for proper operation.
Note. Invert grate in heater body when liquid fuel burner is
used.
a. Removal. Refer to
figure 3-3 and remove the drip
a. Removal.
valve from the burner assembly.
b. Cleaning and Inspection.
(l) Clean all parts in clean fuel or unapproved
cleaning solvent.
b. Cleaning and Inspection.
(2) Inspect valve parts for evidence of damaged
(1) Clean ashes, soot, and clinkers from heater
threads and excessive wear. Inspect sight glass for
body.
broken condition.
(2) Inspect heater body for broken welds and ex-
(3) Replace a defective drip valve.
cessively warped condition.
c. Installation. Refer to
figure 3-3 and install the
(3) Inspect door for warped condition and for
drip valve on the burner assembly.
broken or missing door latch.
d. Test. Light burner to test drip valve for proper
(4) Inspect burner hole cover plate for damage.
operation.
(5) Inspect folding legs for damaged condition.
c. Installation.
(1) Install the grate in the heater body (para
grate from the burner body.
b. Cleaning. Clean rust and carbon deposits from
grate.
Section IX. TROUBLESHOOTING
listed in table 3-2. Each malfunction stated is fol-
lowed by a list of probable causes of the trouble. The
This section provides information useful in diagnos-
corrective action recommended is described opposite
ing and correcting unsatisfactory operation or fail-
the probable cause.
ure of the heater. Malfunctions which may occur are
Section X. ORGANIZATIONAL MAINTENANCE
facture guy lines from cotton cord, allowing 15 feet
of cord for each line.
c. Installation. Refer to figure 3-1 and attach the
guy lines from the flue cap.
guy lines to the flue cap.
b. Repair. Replace guy lines as required. Manu-
Section XI. SHIPMENT AND LIMITED STORAGE
3-31. Preparation of
Equipment for Shipment
Within Zone of Interior
paragraph. Preservation will be accomplished in
sequence that will not require the operation of pre-
a. General. Detailed instructions for the prepara-
viously preserved components.
tion for domestic shipment are outlined within this