TM 10-4520-261-12&P
SPACE HEATER ARCTIC (SHA)
0005 00
OPERATION UNDER USUAL CONDITIONS
0005 00-11
OPERATION IN LIQUID FUEL MODE
Includes the preparation, operation, shutdown, and disassembly instructions for the SHA when operating
with liquid fuel.
PREPARING THE SHA FOR LIQUID FUEL OPERATION
WARNING!
Fire or Explosion
If fuel flow control valve assembly is improperly positioned or if bracket is
bent, a fuel overflow could occur inside burner shell and cause a fire or
explosion.
Slide fuel flow control valve bracket (1) from front to back fully into the sleeve (2) on the right side of the
heater. Be certain that the control valve (3) is fully seated in the sleeve, does not bind in the sleeve, and
is level with heater (4) when installed.
Reach into the cutout area (5) on the right side of the SHA and pull out the control valve fuel discharge
hose (6).
Connect control valve fuel discharge hose QD connector (7) to fuel discharge fitting (8) on base of control
valve (3).
Connect fuel overflow hose (9) to fuel overflow fitting (10).
Connect fuel supply hose (11) to fuel inlet fitting (12).
WARNING!
Fire or Explosion
Heat or sparks from stack assembly could ignite fuel supply. Set up fuel
supply on a clear site seven feet (2.13 meters) or more from shelter and
away from open flame sources.