TM 10-4520-261-12&P
SPACE HEATER ARCTIC (SHA)
0005 00
OPERATION UNDER USUAL CONDITIONS
0005 00-13
WARNING!
Fire or Explosion
Do not use any fuel not authorized in this manual! Use of unauthorized
fuel may result in fire/explosion!
INSTALL GRAVITY FEED ADAPTOR IN FUEL CAN
At the fuel supply site, install a gravity feed adaptor on a full fuel can (filled with fuel as specified in WP
0002) as follows:
WARNING!
Fire or Explosion
Gravity feed adaptor kit must be fully seated to prevent fuel leakage and fire.
Set fuel ON/OFF control (1) on the fuel flow control valve (2) to the OFF position.
Remove cap (3) from mouth (4) of fuel can (5), and replace with gravity feeder adaptor (6). Screw the
adaptor into the fuel can securely.
Attach male end (7) of fuel supply hose (8) to gravity feed adaptor fitting (9). Set the assembled fuel can
aside.
At the fuel supply site, set up fuel can stand (optional item, refer to AAL WP0045) with fuel can (5) level or
slightly above heater as detailed in the next section.
1
2
3
5
4
6
8
9
7