TM 10-4520-261-12&P
SPACE HEATER ARCTIC (SHA)
0005 00
OPERATION UNDER USUAL CONDITIONS
0005 00-14
NOTE!
If fuel can stand (optional item; refer to WP0045) is unavailable, invert
fuel can with installed gravity feed adaptor on a stable support so that the
bottom of the fuel can is two feet (61 centimeters) to three feet (91.5
centimeters) above fuel flow control valve.
Setting up the Fuel Can Stand (optional item; refer to AAL, WP 0045). If liquid fuel is to be used, the
fuel can stand (optional item; the fuel can stand is available as an Additional Authorized Item as detailed
in WP 0045) must be assembled in order to mount the fuel can in the proper position. The fuel can,
outfitted with a fuel can gravity feed adaptor, must be mounted to the stand with the gravity feed adaptor
facing down.
Insert the bottom leg assembly (1) into the top leg assembly
(2) until each leg is locked in place. Be sure to orient each
bottom leg so that the stabilizing straps (3) are positioned
toward the inside of the stand. Ensure that the straps are not
twisted.
Spread the assembled leg assembly (4) until the stabilizing
straps (3) are fully extended and the stand is stable.
The leg assembly straps are designed to ensure the stand is
stable, but are also designed to prevent the stand from
sinking into snow.
1
2
3
4
3