TM 9-4520-251-14
4-59 NOZZLE AND NOZZLE ADAPTER ASSEMBLY (CONT)
Location/Item
Action
Remarks
REMOVAL
When repairing or replacing
container.
NOTE
fuel lines, gasoline may drain out. Drain into
4.
Nozzle
Loosen thumbscrew (2)
and pull out nozzle
holder (l). It can be
pulled away from noz
zle adapter (3) about
8 inches (203 mm).
Unscrew nozzle (6).
Disconnect fuel tube
(7) at tube nut (8). Dis-
5.
Nozzle
holder
connect fuel tube (9) at
tube nut (10). If step 4
has not been completed,
loosen thumbscrew (2)
and pull nozzle holder
(1) and nozzle (6) free
of nozzle adapter (3).
Unscrew nozzle.
SERVICE/REPAIR
Dry cleaning solvent P-D-680 used to clean parts is potentially dan-
gerous to personnel and property. Flash point of solvent is 100° to
138°F (38° to 59°C).
Avoid repeated and prolonged skin contact.
Do not use near open flame or excessive heat.
Death or severe injury might result when compressed air is used to
blow dirt from skin or clothing. Air entering body openings is extreme-
Iy dangerous. Compressed air used for cleaning shall not exceed 100
psi (690 kPa). Use goggles or face shield for eye protection.
6.
Nozzle
Disassemble and clean with solvent. Inspect parts
for damage and wear. Blow dry with compressed
air. Reassemble or replace if defective.
7.
Nozzle
Check for cracks and damaged threads. Clean with
holder
solvent. Blow dry with compressed air. Replace if
defective.