TM 9-4520-251-14
4-60 COMBUSTOR
This task covers:
a. Removal
c. Service
b. Inspection
d. Installation
INITIAL SETUP
Tools
Equipment Condition Para
Condition Description
Tool kit, service, refrigeration unit
459
Nozzle holder removed.
(Appendix B, Section Ill, Item 1)
Materials/Parts
Soft-bristle brush
Dry cleaning solvent (Item 15, Appendix E)
Combustor
Gasket
Location/Item
Action
Remarks
REMOVAL
1. High tension
cable and
igniter
2.
Nozzle
adapter
3.
Plate
4. Combustor
Disconnect high tension cable (1) and remove
igniter (2).
Remove screws (3) and washers (4) and set noz
zle adapter (5) aside for reassembly.
Release overcenter clamps (6) and remove
plate (7).
Remove nuts (8) and washers (9). Lift com
buster (10) and gasket (11) off welded screws
(12). Discard gasket.
4-147