T M 9 - 4 9 3 1 - 3 8 1 - 1 4 & P - 2
FRAME 13
Replace R1 or C1:
WARNING
Sealing compound can burn easily and give off harmful
vapors.
To avoid injury, keep away from open fire and use
in a welI-ventiIated area.
1.
Bond resistor R1 (1) to frame (2) with sealing compound.
2. Measure and cut new insulation sleeving (3) with rule and knife, and slide insulation
sleeving (3) over resistor R1 leads (4).
NOTE
During step 2, if replacing capacitor C1 (5), solder negative
lead of capacitor C1 (5) to resistor R1 (1) and positive lead
of capacitor C1 (5) to harness wire (6) attached tO E10 (7).
3. Solder resistor R1 (1) to negative lead of capacitor C1 (5) and to harness wire (8)
attached to E2 (9).
4. Bond solder connection (10) between resistor R1 (1) and capacitor C1 (5) away from
frame (2) with sealing compound so that connector (1) does not contact frame (2).
Follow-on Maintenance:
1. InstalI cover; refer to task 17.
2. InstalI IDU assembly A2; refer to task 18.
3. Install thermal system test controlIer; refer to para. 2-5, task 2.
4. Install thermal system test controller case cover; refer to volume 1, para. 4-17.
TASK 8 ENDS HERE
Volume IV
Para. 2-8, Task 8
2 - 1 8 1 / ( 2 - 1 8 2 b l a n k )