Inspection
(1)
Inspect connection for secure mounting, burnt, broken, or bent terminals, and corrosion.
(2)
Inspect cable for cracked, burned, or deteriorated insulation and exposed conductor.
(3)
Inspect lug terminals for secure mounting and signs of burning, and corrosion.
(4)
Inspect fitting on unit for damage. If damaged, notify Direct Support.
c.
Repair (Refer to Figure 4-75)
(1)
Repair of cable assembly consists of replacing damaged parts with new parts. If cable (1)
is damaged the complete assembly must be replaced.
(2)
Cut strap (2) from connector plug (3) and remove cover assembly (4).
(3)
Remove two screws (5), two nuts (6) and two saddles (7).
(4)
Unscrew clamp (8) and slide clamp, grommet follower (9), grommet (10), and rubber
bushing (11) down on cable (1).
(5)
Unscrew sleeve (12) from connector plug (3) and down on cable (1).
(6)
Tag three wires (13, (14) and (15).
(7)
Cut connector plug (3) from cable (1).
(8)
Slide sleeve (12), bushing (11), grommet (10), grommet follower (9), and clamp (8) from
cable (1).