TM 9-4931-381-14&P-2
Replace Fuseholder (Continued):
1.
Measure and cut new insulation sleeving M23053/5-109-0 (1) for wire (2) and
fuseholder contact (3) with rule and knife. Slide sleeving (1) over wire (2).
2.
Measure and cut new insulation sleeving M23053/5-111-0 (4) for wire (5) and
fuseholder contact (6) with rule and knife. Slide sleeving (4) over wire (5).
3.
Solder wire (2) to contact (3) and solder wire (5) to contact (6).
4.
Slide sleeving (1 and 4) over contacts (3 and 6) and shrink sleeving (1 and 4) with
thermal gun.
5.
Apply thin fiIm of grease to threads of cannister cap (7) with brush.
6.
Screw on and hand-tighten retaining ring (8) to cannister cap (7). Slide protective
covers (9 and 10) on cannister (11).
GO TO FRAME 5.2
Volume IV
Para. 3-6, Task 2
Change 1 3-16.1