T M 9 - 4 9 3 1 - 3 8 1 - 1 4 & P - 2
FRAME 2
Remove Panel Assembly (Continued):
1.
2.
3.
4.
5.
Unscrew but do not take out two electrical polarizing keys (1) from each of three
receptacle connectors A1P3 (2), A1P1 (3), and A1P4 (4) with flat tip screwdriver.
Take off connector A1P3 (2) from receptacle connector W14J1 (5). Take off
connector A1P1 (3) from receptacle connector W17J1 (6). Take off connector A1P4
(4) from receptacle connector W13J2 (7).
Turn handle (8) one-quarter turn counterclockwise. Take off receptacle connector
A1P2 (9) from receptacle connector W16J1 (10) by pulling up on handle (8).
Look at connectors A1P1 (3), A1P2 (9), A1P3 (2), and A1P4 (4) and connectors W16J1
(10), W14J1 (5), W17J1 (6), and W13J2 (7) for cracks and bent or loose contacts. If
bad, refer to paragraph 2-4 on repairing connectors (if working on plug A1P2 (9),
polarizing keys (11) and handle (8) maybe removed if necessary).
Cut electrical tiedown strap (12) from harness.
GO TO FRAME 3
Volume IV
2-34
Para. 2-6, Task 1