TM 5-3895-377-13&P
2-14.
OPERATING PROCEDURES (CONT).
(1)
Remove straps (1) and power cable (2) from cable reel (3)
WARNING
DO NOT attempt to connect or disconnect wires while generator is in operation
Serious injury or death may occur as a result Always ensure generator is shut
down before any connection or disconnection of wiring is done Always ensure
generator and Heater are properly grounded before attempting to connect or
disconnect any wiring.
(2)
Attach power cable (2) to 15 kW, 60 Hertz generator, NSN 6115-00-118-1241 or NSN 6115-01-274-7388.
Refer toTMN5-6115-464-12 or TM5-6115-643-10 as required) Do not start generator
(3)
Unscrew and lift cover (4) from connector (5).
(4)
Aline notch on connector (5) with tab on power inlet (6)
(5)
Install connector (5) In power inlet (6) Tighten nut (7)
(6)
Start generator (Refer to TM5-6115-464-12 or TM5-6115-64:3-10 as required)
2-20