TM 5-3895-377-13&P
e.
Installing Transfer Hoses (cont).
(3)
Pumping from external source to external system.
WARNING
Oil is slippery and can cause falls. Wipe up spilled oil with rags.
Transfer oil will become extremely hot during operation. Be careful not to touch the hot
oil or allow hot oil to come in contact with skin. Transfer oil can become hot enough to
cause serious burns or death to personnel.
NOTE
Ensure that all valves are closed before removing caps. Failure to do so may result
in drainage of oil from system.
(a)
Remove two transfer hoses (1) from hose trough.
(b)
Place drain pan under EXTERNAL INPUT port (2) and
(c)
Remove two caps (4) from EXTERNAL INPUT port (2) and OUTLET port (3)
(d)
Install nuts (5) on coupling sections (6).
(e)
Install coupling sections (6) on EXTERNAL INPUT port (2) and OUTLET port (3) on Heater
(f)
Install coupling sections (7) on transfer hoses (1).
(g)
Install transfer hose (1) on EXTERNAL INPUT port (2) and external source and tighten nuts (5).
(h)
Install transfer hose (1) on OUTLET port (3) and external system and tighten nuts (5).
NOTE
Ensure that Valves No. 1, 2, and 3 are in the "CLOSED" position to allow proper
pumping operation.
(i)
Check for leaks If leaks are present, check connections for proper fit.
2-25