TM 5-3895-377-13&P
e.
Installing Transfer Hoses.
(1)
Circulating through external system.
WARNING
Oil is slippery and can cause falls Wipe up spilled oil with rags.
Transfer oil will become extremely hot during operation. Be careful not to touch the hot oil
or allow hot oil to come in contact with skin. Transfer oil can become hot enough to cause
serious burns or death to personnel.
NOTE
Ensure that all valves are closed before removing caps. Failure to do so may result
in drainage of oil from system.
(a)
Remove two transfer hoses (1) from hose trough.
(b)
Place drain pan under RETURN port (2) and OUTLET port (3)
(c)
Remove two caps (4) from RETURN port (2) and OUTLET port (3).
(d)
Install two nuts (5) on two coupling sections (6)
(e)
Install coupling sections (6) on RETURN port (2) and OUTLET port (3) on Heater
(f)
Install coupling sections (7) on transfer hoses (1).
(g)
Install transfer hose (1) to RETURN port (3) on Heater and RETURN port on melter and tighten nuts (5)
(h)
Install transfer hose (1) to OUTLET port (4) on Heater and inlet port on melter and tighten nuts (5).
2-21