TM 9-4520-258-14
5-6. HEAT EXCHANGER ASSEMBLY - continued.
f.
Installation - continued (Refer to Figure 5-20)
(5)
Apply anti-seize compound (Item 3, App E) to six screws (1). Install six flat washers (2), six
lockwashers (3), and six screws (1). Hand tighten only.
(6)
Align the front mounting tabs on heat exchanger (4) with the front of unit.
(7)
Install fourteen flat washers (5), seven screws (6), seven lockwashers (7), and seven nuts (8).
(8)
Tighten all the hardware installed in steps (2) and (5).
(9)
Apply anti-seize compound (Item 3, App E) to six screws (9). Install heat exchange shield (10), six flat
washers (11), six lockwashers (12) and six screws (9).
Figure 5-20. Heat Exchanger, Installation
5-34