T M 9 - 4 9 3 1 - 3 8 1 - 1 4 & P -2
FRAME 34
Install Circuit Breaker:
1.
Put newcircuit breaker (1) through hole in panel assembly (2) so new locating flange
(3) fits into slot (4).
2.
Screw on and tighten new nut (5), two new flat washers (6), and new locating flange
(3) with handle and socket.
3. Solder wires (7) to terminals (8).
WARNING
Potting compound is toxic and extremely flammable. Use
only in welI ventiIated areas. Avoid prolonged or repeated
breathing of vapors.
Avoid prolonged contact with skin.
Keep the area free of sparks and open flames.
4.
Put potting compound on circuit breaker (1).
Follow-on Maintenance:
1. InstalI thermal system test controller; refer to para. 2-5, task 8.
2. Install thermal system test controller case cover; refer to volume 1, para. 4-18.
GO TO FRAME 35
2 - 82
Volume IV
Para. 2-6, Task 16