T M 9 - 4 9 3 1 - 3 8 1 - 1 4 & P -2
TASK 14. Install Receptacle Connector Body A5J1, A5J2, or A5J3.
Applicability: AlI Models
Common Tools:
Bit, cross tip, No. 1
Screwdriver, cross tip, No. 1
Special Tools:
Wrench Set, socket, 12285468
Supplies:
Lockwasher (96906) MS35338-135 (four required per connector)
Personnel: One
Equipment Condition:
Thermal system test controller on a clean work surface.
Preliminary Procedure:
Remove receptacle connector body A5J1, A5J2, or A5J3; refer to task 3.
2-312
Volume IV
Para. 2-11, Task 14